Skip to content
DensDeck Prime Roof Board

DensDeck Prime Roof Board

DensDeck Prime Roof Boards by Georgia-Pacific Gypsum are a patented design features a gypsum core with embedded glass mat facers on the top and bottom of the board. DensDeck Prime can be used in a variety of commercial roof systems and provides an excellent thermal barrier as well as exceptional fire, moisture, and wind uplift resistance properties.

DensDeck Prime is typically used as a cover board over insulation in fully adhered EPDM, TPO, and PVC applications. It is compatible with solvent-based bonding adhesives. For applications in which Helix Max is used to attach insulation and a vapor barrier is specified, DensDeck Prime can be used as a base layer for Mule-Hide’s F5 Air and Vapor Barrier (in conjunction with Aeroweb). DensDeck Prime is also compatible with hot asphalt and can be used as a membrane underlayment in hot mopped roofing systems or as a parapet wall substrate in all systems.

System

EPDM
TPO
PVC
ModBit
  • UL code ratings available for (class A, B, C) unlimited slopes and wood decks
  • FM Approved
  • Improves resistance to foot traffic and hail damage
  • Excellent wind uplift ratings
  • Resistant to deterioration, warping, and jobsite damage
  • ⅝" DensDeck Prime can replace any generic Type “X” gypsum board in any roof assembly in the UL Fire Resistance Directory under the prefix “P”
  • Meets  UL Standards
  • Meets  FM Standards

Documents

DensDeck Glass Mat Faced Gypsum Panels Safety Data Sheet
PDS DensDeck Prime Roof Board
Tech Data Sheet - DensDeck Prime Roof Board

Single-Ply Roofing Accessories Guide
Tech Bulletin - DensDeck Prime Roof Board
Tech Bulletin - Preparation of DensDeck in Modified Bitumen Systems

Details

2 inch OR THICKER INSULATION ATTACHMENT - 8 FASTENERS PER 4ft X 8ft BOARD
FM - 12 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 16 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 17 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 8 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
INSULATION ATTACHMENT - 12 FASTENERS PER 4ft X 8ft IN FIELD
INSULATION ATTACHMENT - 16 FASTENERS PER 4ft X 8ft IN FIELD
INSULATION ATTACHMENT PATTERNS FOR MECHANICALLY ATTACHED SYSTEMS
INSULATION ATTACHMENT WITH MODBIT - 16 FIELD FASTENERS PER 4FT X 8FT BOARD - OPTION 1
INSULATION ATTACHMENT WITH MODBIT - 17 FIELD FASTENERS PER 4FT X 8FT BOARD- OPTION 5
INSULATION ATTACHMENT WITH MODBIT - 24 FIELD FASTENERS PER 4FT X 8FT BOARD - OPTION 3
INSULATION ATTACHMENT WITH MODBIT - 28 FIELD FASTENERS PER 4FT X 8FT BOARD - OPTION 4
INSULATION ATTACHMENT WITH MODBIT - 8 FIELD FASTENERS PER 4FT X 8FT BOARD - OPTION 2