Mule-Hide PVC Fleece Back membrane is used in mechanically attached and fully adhered roofing systems in new construction, reroofing and recover (retrofit) applications. PVC standard membrane (non-fleece back) is to be used as flexible membrane flashings for walls, curbs, etc, when installing PVC Fleece Back roofing systems. The system must be installed over acceptable roof insulation or other suitable substrate.

System

PVC
  • Fleece backing adds toughness, durability and enhanced puncture resistance
  • Polyester reinforcement provides excellent breaking strength
  • Use of Low-volatility plasticizer
  • Enhanced chemical resistance to acids, bases, restaurant oils, fats, greases and acid rain
  • Low temperature flexibility
  • Excellent wind uplift resistance due to bond between fleece and adhesive
  • Meets  UL Standards
  • Meets  C-UL Standards
  • Meets  FM Standards
  • Meets  CCMC Standards
  • Meets  Miami-Dade-County Standards
  • Meets  Florida-Building Standards
  • Meets  CRRC Standards
  • Meets  CA-Title-24 Standards

Documents

PDS PVC Fleece Back Membrane

CCMC - Canadian Construction Materials Centre evaluation for PVC Systems
Florida Product Approval - HVHZ - PVC Systems
Florida Product Approval - PVC Systems
ICC-ESR Report - Adhered and Mech. Attached EPDM Systems, TPO Systems & PVC Systems
TDI - Texas Department of Insurance - TPO Systems & PVC Systems MA over wood
UL - Impact resistance ratings for PVC Systems
UL - Overview of UL Listings for PVC Systems

Hail Coverage - Procedures and Requirements
Letter of Compliance Application- Photovoltaic Installation on Mule-Hide Warranted Roof
Procedure for Inclusion of Photovoltaic Anchor Flashings
PVC Cross Reference Chart
PVC Metal Retrofit
PVC Pocket Guide
PVC Pocket Guide (Spanish)
PVC Systems Contractor Brochure
Sell Sheet - Fleece Back Recovery System
Sell Sheet - Why Choose PVC
Single-Ply Roofing Accessories Guide

Design Enhancements - Single-Ply Membranes
Design Summary - PVC Fleece Back Systems 10 or 15 year Fully Adhered
Design Summary - PVC Systems 10 or 15 year Fully Adhered
Design Summary - PVC Systems 10 or 15 year Mechanically Attached
E-Z Residential (Single-Family) Warranty Application - Material Only
Warranty - Notice of Completion
Warranty Program Information - Heat Weld Systems

Details

BASE ATTACHMENT PVC - ALL-PURPOSE BAR
PARAPET FLASHING FOR PVC

FIELD FABRICATED INSIDE CORNER FOR PVC
FIELD FABRICATED OUTSIDE CORNER FOR PVC
PRE-MOLDED INSIDE CORNER FLASHING FOR PVC
PRE-MOLDED OUTSIDE CORNER FOR PVC

CURB FLASHING FOR PVC
DRAIN FLASHING WITH TARGET - FLEECE BACK

DRAIN FLASHING WITH TARGET - FLEECE BACK
PREMANUFACTURED CONDUCTOR HEAD

EXPANSION JOINT - DECK TO DECK
EXPANSION JOINT - DECK TO DECK FOR PVC
EXPANSION JOINT AT JUNCTION OF DECK AND WALL
EXPANSION JOINT AT JUNCTION OF DECK AND WALL FOR PVC

CONCRETE PAVER WALKWAY
MH-100 PVC Walkway

2 inch OR THICKER INSULATION ATTACHMENT - 8 FASTENERS PER 4ft X 8ft BOARD
FM - 10 Field Fasteners per 4'x8' Board
FM - 12 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 16 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 17 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 8 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 8 Field Fasteners per 4'x8' Board
HELIX MAX FOAM ADHESIVE 12" RIBBON PATTERN
HELIX MAX FOAM ADHESIVE 4" RIBBON PATTERN
HELIX MAX FOAM ADHESIVE 6" RIBBON PATTERN
INSULATION ATTACHMENT - 12 FASTENERS PER 4ft X 8ft IN FIELD
INSULATION ATTACHMENT - 16 FASTENERS PER 4ft X 8ft IN FIELD
INSULATION ATTACHMENT - 17 FASTENERS PER 4ft X 8ft IN FIELD

MEMBRANE SECUREMENT FOR PVC
PERIMETER ATTACHMENT FOR PVC
ROOF PERIMETER/CORNER CALCULATIONS ELEVATION DIFFERENCE 3ft OR LESS FOR PVC
ROOF PERIMETER/CORNER CALCULATIONS ELEVATION DIFFERENCE GREATER THAN 3ft FOR PVC

FIELD FABRICATED HOT PIPE FOR PVC
FIELD FABRICATED PIPE FLASHING FOR PVC
MEMBRANE COATED METAL PITCH PAN FOR PVC
MOLDED SEALANT POCKET FOR PVC
PREFABRICATED SQUARE TUBING WRAP FOR PVC
PVC PRE-MOLDED PIPE FLASHING
SLEEPER SUPPORT (HEAVY WEIGHT) FOR PVC - OPTION 2
SLEEPER SUPPORT (HEAVY WEIGHT) FOR PVC - OPTION 3
SLEEPER SUPPORT (LIGHT WEIGHT) FOR PVC - OPTION 1

ALL-PURPOSE BAR EDGE TERMINATION FOR PVC
COATED METAL BUTT JOINT FOR PVC
DRIP EDGE FOR ALL PVC SYSTEMS
EDGE TERMINATION - ALL-PURPOSE BAR FOR PVC
GUTTER TERMINATION FOR FLEECE BACK PVC
MEMBRANE COATED GRAVEL STOP FOR PVC
WOOD NAILER ATTACHMENT FOR PVC

"T" JOINT COVER PATCH .060" (60 MIL) OR THICKER MEMBRANES
FLEECE BACK END LAPS FOR PVC
T-JOINT DETAIL 50 MIL MEMBRANE FOR PVC

CONCRETE PARAPET WALL WITH TERMINATION BAR FOR PVC
COPING STONE FOR PVC
CURB/WALL FLASHING WITH COUNTERFLASHING FOR PVC
CURB/WALL FLASHING WITH M-H ALL-PURPOSE BAR FOR PVC
METAL CAP TERMINATION FOR PVC
PREMANUFACTURED ARCHED COPING WITH SPLICE PLATE
PREMANUFACTURED METAL EDGE EXTENDER
PREMANUFACTURED REGLET COUNTERFLASHING
PREMANUFACTURED SURFACE MOUNTED COUNTERFLASHING
REGLET COUNTERFLASHING TERMINATION FOR PVC
SURFACE MOUNTED COUNTERFLASHING FOR PVC
TERMINATION BAR AT CORNER FOR PVC
TERMINATION BAR AT TILT-UP WALL JOINT FOR PVC
TERMINATION BAR FOR PVC
TERMINATION BAR WITH COUNTERFLASHING FOR PVC
TERMINATION ELEVATION CHANGE FOR PVC

COATED METAL TRANSITION TO SHINGLE ROOF FOR PVC
MEMBRANE FLASHING TRANSITION TO SHINGLE ROOF FOR PVC
TIE-IN TO EXISTING SINGLE PLY FOR PVC

Specifications

Specification - PVC Systems - PVC Systems KEE Fully Adhered Fleece Back
Specification Supplement - AeroWeb Adhesive
Summary Specification - PVC Fleece Back Systems Fully Adhered
Summary Specification - PVC Systems Fully Adhered

Guide - Equipment needed to install Heat-Welded Membranes
Guide - Insulation Guidelines
Guide - PVC Systems HydroBOND Installation Guide
Guide - PVC Systems Installation Guidelines
Guide - Roof Mounted Photovoltaic Installations
Single-Ply Insulation Attachment Guidelines
Tech Note - Design Wind Speed vs Warranted Wind Speed
Tech Note - Sheet Flutter on Mechanically Attached Systems

Specification - PVC Systems Mechanically Attached
Summary Specification - Induction Welding Attachment Method
Summary Specification - PVC Fleece Back Systems Mechanically Attached
Summary Specification - PVC Systems Mechanically Attached
Summary Specification - PVC Systems metal retrofit attached into purlins

Options

Item ID Description Packaging Qty per Ctn Weight per Ctn Cover Rate
07MHPF357G MH PVC 135 10X75 FLEECEBACK GRY Shrink Wrap 1 452 750 Sq.Ft/RL
07MHPF357T MH PVC 135 10X75 FLEECEBACK TAN Shrink Wrap 452 750 Sq.Ft/RL
07MHPF357W MH PVC 135 10X75 FLEECEBACK WHT Shrink Wrap 452 750 Sq.Ft/RL
07MHPF151G MH PVC 115 10X100 FLEECEBACK GRY Shrink Wrap 460 1000 Sq.Ft/RL
07MHPF151T MH PVC 115 10X100 FLEECEBACK TAN Shrink Wrap 460 1000 Sq.Ft/RL
07MHPF151W MH PVC 115 10X100 FLEECEBACK WHITE Shrink Wrap 1 460 1000 Sq.Ft/RL

FAQs

To reduce blocking, packs should only be stacked 4-packs up to five high. We have found that when stacked higher, the bottom rolls could crush a bit which could create blocking and a wavy sheet when installed. It is possible that the stacking issue can be heightened over the summer months due to the heat.