Skip to content
TPO with Clean Film

TPO with Clean Film

Is available with an optional CLEAN Film, a temporary protective film factory applied to the top surface of the membrane. By protecting the membrane surface from scuffs and dirt accumulation during installation, this protective film can save labor and time by helping to eliminate the need for roof cleaning upon project completion. CLEAN Film can be left in place for up to 90 days. Durable and easy to remove, CLEAN Film helps to improve the aesthetics and long-term reflectivity and is ideal for use on re-roofing, re-cover and new construction projects. CLEAN Film is available on TPO-c 60 mil membranes supplied in 6’ x100’ and 10’x100’rolls.

System

TPO
  • Polyester-reinforced
  • Available in 6' and 10' widths only
  • 60 mil thickness
  • Fully adhered and mechanically attached systems
  • Available in white, gray and tan
  • Most often installed as mechanically attached
  • Up to a 20 year system warranty available
  • All adhesives must be installed as a 2-sided contact adhesive
  • Pre-printed with lap lines and fastener spacing
  • Meets  UL Standards
  • Meets  C-UL Standards
  • Meets  FM Standards
  • Meets  CCMC Standards
  • Meets  Miami-Dade-County Standards
  • Meets  Florida-Building Standards
  • Meets  CRRC Standards
  • Meets  CA-Title-24 Standards
  • Meets  ICC-ES Standards

Documents

PDS Standard TPO Membranes
SDS - Statement for Article Products

CCMC - Canadian Construction Materials Centre evaluation for TPO Systems
Florida Product Approval - TPO Systems
Florida Product Approval HVHZ - TPO Systems
ICC-ESR Report - Adhered and Mech. Attached EPDM Systems, TPO Systems & PVC Systems
ICC-ESR Report - Ballasted EPDM Systems and TPO Systems
Miami-Dade NOA - TPO Systems over Cement Wood Fiber
Miami-Dade NOA - TPO Systems over Concrete Deck
Miami-Dade NOA - TPO Systems over Gypsum
Miami-Dade NOA - TPO Systems over Light Weight Concrete
Miami-Dade NOA - TPO Systems over Steel Deck
Miami-Dade NOA - TPO Systems Recover applications
TDI - Texas Department of Insurance - TPO Systems & PVC Systems MA over wood
TPO Membrane - EPD
UL - Impact resistance ratings for TPO Systems
UL - Overview of UL Listings for TPO Systems
UL - Summary of UL Listings for TPO Systems

Eight Reasons to Choose a TPO System
Hail Coverage - Procedures and Requirements
Letter of Compliance Application- Photovoltaic Installation on Mule-Hide Warranted Roof
Procedure for Inclusion of Photovoltaic Anchor Flashings
Reduced Fastener Requirements for Uplift Ratings
Single-Ply Roofing Accessories Guide
Talking Points - TPO with CLEAN Film
Tech Bulletin - Pactiv GreenGuard Insulation
TPO Cross Reference Chart
TPO Metal Retrofit
TPO Pocket Guide
TPO Pocket Guide (Spanish)
TPO Systems Brochure

Design Enhancements - Single-Ply Membranes
Design Summary - TPO Fleece Back Systems 10 or 15 year Fully Adhered
Design Summary - TPO Systems 10 or 15 year Ballasted
Design Summary - TPO Systems 10 or 15 year Fully Adhered
Design Summary - TPO Systems 10 or 15 year Mechanically Attached
E-Z Residential (Single-Family) Warranty Application - Material Only
Warranty - Notice of Completion
Warranty Program Information - Heat Weld Systems

Details

BASE ATTACHMENT TPO- ALL -PURPOSE BAR
BASE ATTACHMENT WITH 6 inch RUSS
BASE ATTACHMENT WITH PLATES AND FASTENERS
DOOR THRESHOLD FLASHING
Rhinobond Base Attachment
RhinoBond Metal Retrofit for TPO
RhinoBond Metal Retrofit for TPO
RhinoBond Metal Retrofit for TPO
RhinoBond Metal Retrofit for TPO

2-PIECE OUTSIDE CORNER UNCURED EPDM
FIELD FABRICATED INSIDE CORNER FOR TPO
FIELD FABRICATED OUTSIDE CORNER FOR TPO
INSIDE CORNER - UNCURED EPDM
INSIDE CORNER FOR TPO
INSIDE CORNER USING RUSS FOR TPO
TPO UNIVERSAL CORNER - OUTSIDE CORNER

CURB FLASHING FOR TPO
CURB FLASHING WITH M-H ALL-PURPOSE BAR
CURB/WALL FLASHING WITH M-H ALL-PURPOSE BAR FOR TPO
INSULATED PARAPET WALL WITH METAL COPING CAP FOR TPO
PARAPET WALL DETAIL - EXISTING COPING CAP FOR TPO
PARAPET WALL DETAIL - METAL COPING CAP FOR TPO
PARAPET/CURB FLASHING FOR EPDM

DRAIN FLASHING - TAPERED INSULATION DRAIN SUM SLOPE LESS THAN 3 inch TO 12 inch FOR TPO
DRAIN FLASHING W/TARGET (PAGE 1 OF 2)
DRAIN FLASHING W/TARGET (PAGE 2 OF 2)
DRAIN FLASHING WITH TARGET PANELS DRAIN SUMP SLOPE GREATER THAN 3 inch TO 12 inch FOR TPO
DRAIN FLASHING WITH TARGET PATCH FOR TPO
DUTCH GUTTER FOR EPDM AND TPO
GRAVEL STOP SCUPPER - TPO COATED METAL
INTERMITTENT WALL SCUPPER FOR EPDM
NEW METAL THROUGH-WALL SCUPPER WITH WHITE UNCURED EPDM FOR TPO
PREMANUFACTURED CONDUCTOR HEAD
RETROFIT DRAIN INSERT - COMPRESSION TYPE INSERT FOR TPO
ROOF DRAIN FOR EPDM AND TPO
THROUGH-WALL SCUPPER - TPO COATED METAL
THROUGH-WALL SCUPPER - TPO COATED METAL

EXPANSION JOINT - CURB FOR TPO
EXPANSION JOINT CURB WITH CLOSED CELL ROD
EXPANSION JOINT DETAIL
EXPANSION JOINT DETAILS
WALL EXPANSION JOINT
WALL EXPANSION JOINT

4" TRAY PROFILE
TRANSITION TO WALKWAY
WALKWAY PAVER FOR EPDM AND TPO

2 inch OR THICKER INSULATION ATTACHMENT - 8 FASTENERS PER 4ft X 8ft BOARD
Extruded Polystyrene Insulation Attachment Fastening Patterns
FM - 12 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 16 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 17 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 8 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
HELIX MAX FOAM ADHESIVE 12" RIBBON PATTERN
HELIX MAX FOAM ADHESIVE 4" RIBBON PATTERN
HELIX MAX FOAM ADHESIVE 6" RIBBON PATTERN
INSULATION ATTACHMENT - 12 FASTENERS PER 4ft X 8ft IN FIELD
INSULATION ATTACHMENT - 16 FASTENERS PER 4ft X 8ft IN FIELD
INSULATION ATTACHMENT - 17 FASTENERS PER 4ft X 8ft IN FIELD
INSULATION ATTACHMENT PATTERNS FOR MECHANICALLY ATTACHED SYSTEMS
Rhinobond Fastening Requirements

FM CORNER/PERIMETER FASTENING ENHANCEMENTS - TPO OPTION A
FM CORNER/PERIMETER FASTENING ENHANCEMENTS - TPO OPTION B
PERIMETER ATTACHMENT - OPTION 1 - PERIMETER HALF SHEETS FOR TPO
PERIMETER ATTACHMENT - OPTION 2 - 10 inch RUSS STRIP ALTERNATE FOR TPO
PERIMETER SECUREMENT - 10 inch RUSS STRIP FOR EPDM
ROOF CORNER AND PERIMETER DETAIL
ROOF PERIMETER/CORNER CALCULATION ELEVATION DIFFERENCE 3ft OR LESS FOR TPO
ROOF PERIMETER/CORNER CALCULATION ELEVATION DIFFERENCE GREATER THAN 3ft FOR TPO
SHEET LAYOUT ON BUILDINGS WITH LARGE OPENINGS FOR TPO
SHEET LAYOUT ON BUILDINGS WITH OVERHANGS FOR TPO

FIELD FABRICATED PIPE FLASHING WITH BANDING CLAMP FOR TPO
FIELD FABRICATED PIPE FLASHING WITH SEAM TAPE FOR TPO
FIELD FABRICATED PIPE FLASHING WITH WHITE UNCURED EPDM
FIXED EQUIPMENT SUPPORT FOR TPO
HOT PIPE FLASHING WITH COLD SLEEVE FOR TPO
HOT PIPE FLASHING WITH COLD SLEEVE WITH UNCURED EPDM
I-BEAM SUPPORT FLASHING FOR TPO
LIGHTNING CABLE STRAP FOR TPO
LIGHTNING ROD BASE FOR TPO
LIGHTNING ROD DETAIL
LIGHTNING ROD WALL SUPPORT FOR TPO
MULTIPLE PIPE PENETRATION FOR TPO
PITCH PAN MEMBRANE COATED METAL FOR TPO
PREFABRICATED SQUARE TUBING WRAP FOR TPO
PRE-MOLDED PIPE BOOT - WHITE EPDM
PRE-MOLDED PIPE BOOT FOR TPO
SLEEPER DETAIL FOR TPO
TPO MOLDED SEALANT POCKET
TPO SPLIT PIPE BOOT
WHITE EPDM PREFABRICATED SEALANT POCKET
WOOD SLEEPER FOR TPO

ALL-PURPOSE BAR - EDGE TERMINATION FOR TPO
ANCHOR-TITE FASCIA SYSTEM BY METAL-ERA, INC
DRIP EDGE - TPO PS COVER STRIP
DRIP EDGE - WHITE EPDM CURED COVER TAPE FOR TPO
DRIP EDGE TPO COATED METAL
EDGE TERMINATION - ALL-PURPOSE BAR FOR TPO
FASCIA / DRIP EDGE SYSTEM FOR TPO
GRAVEL STOP - TPO COATED METAL - OPTION 1
GRAVEL STOP - TPO COATED METAL - OPTION 2
GRAVEL STOP JOINT DETAIL - TPO COATED METAL
GUTTER / TERMINATION BAR - RECOVER FOR TPO
GUTTER / TERMINATION BAR - RECOVER FOR TPO
GUTTER DRIP EDGE - TPO COATED METAL
METAL RETROFIT - MEMBRANE COATED DRIP EDGE WITH GUTTER FOR TPO
PREMANUFACTURED 2-PIECE COMPRESSION LARGE EDGE DETAIL FOR TPO
PREMANUFACTURED ARCHED DRIP EDGE WITH SPLICE CLIP FOR TPO
PREMANUFACTURED MEMBRANE COATED METAL PITCH PAN FOR TPO
SNAP-ON FASCIA FOR TPO
TAPERED EDGE / GRAVEL STOP FOR TPO

END LAPS FOR TPO
FIELD SEAM - PLATE POSITION FOR TPO
FIELD SEAM ATTACHMENT
FIELD SEAM FOR TPO
MEMBRANE / SEAM REPAIR WHITE MATE-LINE TAPE
METAL RETROFIT - 10 inch RUSS RIDGE SECUREMENT DETAIL FOR TPO
METAL RETROFIT - 10 inch RUSS STRIP MEMBRANE SECUREMENT FOR TPO
METAL RETROFIT - 100 MPH OR LESS WIDE SHEETS WITH SEAMS OVER PURLINS FOR TPO
METAL RETROFIT - 100 MPH OR LESS WIND ZONES MECHANICALLY ATTACHED SYSTEM FOR TPO - OPTION 1
METAL RETROFIT - 100 MPH OR LESS WIND ZONES MECHANICALLY ATTACHED SYSTEM FOR TPO - OPTION 2
METAL RETROFIT - 101-120 MHP WIND ZONES MECHANICALLY ATTACHED FOR TPO - OPTION 1
METAL RETROFIT - 101-120 MHP WIND ZONES MECHANICALLY ATTACHED FOR TPO - OPTION 2
METAL RETROFIT - 101-120 MHP WIND ZONES MECHANICALLY ATTACHED FOR TPO - OPTION 3
METAL RETROFIT - 101-120 MHP WIND ZONES MECHANICALLY ATTACHED FOR TPO - OPTION 4
METAL RETROFIT - 101-120 MHP WIND ZONES NARROW SHEETS WITH SEAMS OVER PURLINS
METAL RETROFIT - SEAM FASTENING NARROW ROLLS MEMBRANE SECUREMENT FOR TPO
SEAM PATCH AT FIELD/WALL TRANSITION FOR TPO
T-JOINT COVER - 60 MIL OR THICKER MEMBRANES FOR TPO
T-JOINT DETAIL - 45 MIL THICK MEMBRANES FOR TPO
UNCURED EPDM SEAM PATCH AT FIELD / WALL TRANSITION
WHITE UNCURED EPDM "T" JOINT COVER .060" (60 MIL) OR THICKER MEMBRANE

BASE FLASHING AT SIDING FOR TPO
CURB/WALL FLASHING WITH COUNTERFLASHING FOR TPO
PREMANUFACTURED ARCHED COPING WITH SPLICE PLATE
PREMANUFACTURED METAL EDGE EXTENDER
PREMANUFACTURED REGLET COUNTERFLASHING
PREMANUFACTURED SURFACE MOUNTED COUNTERFLASHING
WALL FLASHING WITH COUNTERFLASHING FOR TPO

SEGREGATION DETAIL/GREEN ROOF AND EXISTING ROOF
SEGREGATION DETAIL/GREEN ROOF AND EXPOSED SINGLE PLY
TIE-IN - EXISTING BUR OR MOD BIT
TIE-IN - SHINGLE ROOF - 6 inch RUSS FOR TPO
TIE-IN - SHINGLE ROOF FOR TPO
TIE-IN TO EXISTING BUR / MOD BIT ROOF - RECOVER SITUATION FOR TPO
TIE-IN TO EXISTING EPDM OR HYPALON - TEAR-OFF SITUATION FOR TPO
TIE-IN TO SOLID DECK WITH CURB - CURB PARALLEL TO SLOPE WITH TEAR-OFF FOR TPO

RIDGE FLASHING FOR TPO
RIDGE SHEET LAYOUT FOR TPO
VALLEY FLASHING - 6 inch RUSS FOR TPO - OPTION 2
VALLEY FLASHING 6 inch RUSS FOR TPO - OPTION 1
VALLEY FLASHING FOR TPO - OPTION 1
VALLEY FLASHING FOR TPO - OPTION 2

Specifications

Specification - TPO Fully Adhered
Specification Supplement - AeroWeb Adhesive
Summary Specification - TPO Systems Fully Adhered

Guide - Equipment needed to install Heat-Welded Membranes
Guide - Insulation Guidelines
Guide - Roof Mounted Photovoltaic Installations
Guide - TPO Systems Installation Guidelines
Single-Ply Insulation Attachment Guidelines
Tech Note - Design Wind Speed vs Warranted Wind Speed
Tech Note - Sheet Flutter on Mechanically Attached Systems

Specification - TPO Systems Induction Welding Attachment
Specification - TPO Systems Mechanically Attached
Specification - TPO Systems RhinoBond Attachment
Summary Specification - TPO Systems Mechanically Attached
Summary Specification - Induction Welding Attachment Method
Summary Specification - TPO Systems Induction Welding Linear Attachment
Summary Specification - TPO Systems metal retrofit using RUSS
Summary Specification - TPO Systems metal retrofit-purlin attached

Options

Item ID Description Packaging Qty per Ctn Weight per Ctn Cover Rate
07MHT611GC MH TPO 060 10X100 GRAY w/CLEAN FILM Shrink Wrap 1 330 1000 Sq.Ft/RL
07MHT611TC MH TPO 060 10X100 TAN w/CLEAN FILM Shrink Wrap 1 330 1000 Sq.Ft/RL
07MHT611WC MH TPO 060 10X100 WHITE w/CLEAN FILM Shrink Wrap 1 330 1000 Sq.Ft/RL
07MHT661GC MH TPO 060 6X100 GRAY w/CLEAN FILM Shrink Wrap 1 198 600 Sq.Ft/RL
07MHT661TC MH TPO 060 6X100 TAN w/CLEAN FILM Shrink Wrap 1 198 600 Sq.Ft/RL
07MHT661WC MH TPO 060 6X100 WHITE w/CLEAN FILM Shrink Wrap 1 198 600 Sq.Ft/RL

FAQs

To reduce blocking, packs should only be stacked 4-packs up to five high. We have found that when stacked higher, the bottom rolls could crush a bit which could create blocking and a wavy sheet when installed. It is possible that the stacking issue can be heightened over the summer months due to the heat.